Inspection and Testing Exam Simulator 60 mins

Welcome to your Inspection and Testing 60 mins

What circumstance would require an Electrical Installation Condition Report to be issued?

The minimum insulation resistance between conductors for an extra-low voltage circuit is?

A simple method to allow for measured values of loop impedance to be effectively compared with BS7671 tabulated maximum values, is to correct these maximum values by multiplying them by?

An approximation of the prospective fault current between line conductors, of a 3 phase supply can be determined by?

With regard to determining the frequency of periodic inspection and testing of an installation, which of the following does not need to be considered?

The minimum insulation resistance between conductors for an extra-low voltage circuit is?

When carrying out an inspection of a new installation, it is not necessary to verify the?

Which of the following statements is incorrect?

Prospective fault current for a single phase supply, is recorded using the highest value determined from the prospective?

Methods of inspection and testing are described in which Guidance Note?

A public library has been refirbished and an additional lighting circuit is to be installed. What would be the most appropriate human sense to use when inspecting the IP rating of the new lights?

A public library has been refirbished and an additional lighting circuit is to be installed. What document must the Inspector use to record the reference method for the new lighting circuit?

A public library has been refurbished and an additional lighting circuit is to be installed. What non-statutory document relates to inspection and testing?

A public library has been refurbished and an additional lighting circuit is to be installed. What document must be completed following inspection and testing?

A public library has been refirbished and an additional lighting circuit is to be installed. The new light fittings are recessed, what is the minimum IP rating required for the fittings?

A public library has been refirbished and an additional lighting circuit is to be installed by your company. Upon Inspection the light fittings, you realise the light fittings do not comply with the minimum IP rating. What action should you take?

A public swimming pool has been refurbished and an additional lighting circuit is to be installed. The new light fittings will be at a height of 2.4m above the pool. What is the minimum IP rating for the new lights?

A new Barn which is part of a dairy farm is being constructed. What is the minimum IP rating for Electrical Equipment to be installed in this location?

A new lighting circuit has been installed in a Sauna, jet wash cleaning is prohibited to prevent damage to equipment. What is the minimum IP rating for the new lights?

A public library has been refirbished and an additional lighting circuit is to be installed. Which test must be carried out before the earth fault loop impedance, to ensure the installation is safe to energise?

The existing installation in a supermarket is to be inspected and tested as a requirement of the insurance policy. Previous inspection and testing records exist but two additional lighting circuits have been installed, which there are test results available for. Where must the Extent and Limitations of the inspection and testing be recorded for the existing circuits??

The existing installation in a supermarket is to be inspected and tested as a requirement of the insurance policy. Previous inspection and testing records exist but two additional lighting circuits have been installed which there is test results available. Who will be involved in setting the sampling size for this installation?

Which document would be completed for an installation of a new garage circuit to an existing installation?

Which document would be completed for an installation of a new shower circuit to an existing installation?

Which document would be completed for an installation of an additional light fitting to an existing circuit?

Which document would be completed for an installation of an additional light fitting to an existing circuit?

Which document would be completed for an installation of a replacement cooker to an existing circuit?

Which document would be completed for an installation of a new cooker circuit to an existing installation?

What process involves checking if a new installation complies with BS7671?

What process involves checking if an installation has been affected by a recent flood incident?

What process involves checking if an installation has been affected by a recent fire incident?

What process involves checking if an existing installation of a rental property meets current standards for a change of tenant?

What process involves checking if an installation has deteriorated?

What needs to be verified during the inspection of a new installation?

The non-statutory document detailing the care and use of tests instruments leads and probes is?

The Electricity at Work Regulations is classed as a?

Although BS7671 is not a statute document compliance with it is considered to comply with the?

The non-statutory document detailing the care and use of test instruments leads and probes is?

The existing installation in a supermarket is to be inspected and tested as a requirement of the insuarance policy. Previous inspection and testing records exist but two additional lighting circuits has been installed which there are test results available. What action should be taken with regard to the additional lighting circuit

The procedure for proving dead should be by use of a proprietary test lamp or two pole voltage detecting device as recommended by?

The most serious result of basic contact with a live conductor would be?

Which of the following is not a requirement of test probes and leads according to GS38?

The correct safe isolation procedure on a 3 phase circuit will result in a voltage indicating device being connected across terminals in how many different combinations to ensure it is adequately proved dead?

The Continuity of a main protective bonding conductor to a water pipe in a dwelling is to be tested. The cable CSA is 10mm and the length is 22m. The installation has been safely isolated for this test. Why must the installation remain safely isolated for this test?

The item shown in the photo serves what purpose?

The safest and most convenient way of proving the reliability of a voltage indicating device is?

The practice of placing insulation tape over a switched circuit breaker during the safe isolation process contravenes which regulation?

If a blank is missing on a distribution board, with access to live parts, what outcome would this be recorded as on an EICR?

If a blank is missing on a distribution board, with access to live parts, what outcome would this be recorded as on an EICR?

If a 20mm knockout is open, has no grommet and there is access to live parts what outcome would this be recorded as on an EICR?

If an installation has no bonding to the water pipes what outcome would this be recorded as on an EICR?

If an installation has no bonding to the gas pipes what outcome would this be recorded as on an EICR?

If an installation has no earth conductor what outcome would this be recorded as on an EICR?

If upon inspection a cracked socket, but no access to live parts was found what outcome would this be recorded as on an EICR?

If upon inspection a cracked socket, with access to live parts was found what outcome would this be recorded as on an EICR?

If upon inspection an undersized cable was found what outcome would this be recorded as on an EICR?

If a shop lighting circuit installed in metal conduit in a supplied from a TN-S system, had no RCD provided for fault protection but achieved disconnection times what would the outcome be on the schedule of inspections?

If upon inspection the label was missing on a bonding clamp, what outcome would this be recorded as on an EICR?

If upon inspection the chart was missing on a shop consumer unit, what outcome would this be recorded as on an EICR?

If upon inspection the label was missing on a circuit breaker, what outcome would this be recorded as on an EICR?

If upon inspection the top of a Distribution Board has an unused opening exceeding IP4X but with no access to live parts, what outcome would this be recorded as on an EICR?

If upon inspection the top of a Distribution Board has an unused opening exceeding IP4X and with no access to live parts, what outcome would this be recorded as on an EICR?

If upon inspection the top of an Isolator has an unused opening exceeding IP4X and with no access to live parts, what outcome would this be recorded as on an EICR?

Which of the following would justify a C2 Code for a Periodic Inspection?

Which of the following would justify a C1 Code for a Periodic Inspection?

If upon inspection there is a socket within 2.5m of Zone 1 in a bathroom, what outcome would this be recorded as on an EICR?

If upon inspection there is a socket greater than 2.5m away from Zone 1 in a bathroom but with no RCD protection, what outcome would this be recorded as on an EICR?

If upon inspection there is a socket with 30mA RCD protection and 2.9m from Zone 1 in a bathroom, what outcome would this be recorded as on an EICR?

If an exposed live part was was found on a socket outlet during an inspection on a periodic report what should the inspector do?

The continuity of a main protective bonding conductor to a water pipe in a dwelling is to be tested. The cable CSA is 10mm and the length is 22m. The installation has been safely isolated for this test. Which additional piece of test equipment will be required for this test?

The insulation resistance test voltage for a SELV installation is?

Following connection of fixed equipment that is likely to be damaged by a test of 500V DC, a test at 250V DC can be applied between live and protective conductors. What is the minimum insulation resistance value required?

An insulation resistance test performed on a standard final circuit, should be set to measure in?

What is the importance of verifying readings obtained with those listed within BS7671 and associated documents?

Which of the following is NOT a scale commonly found on an RCD tester?

GN3 recommends that a low resistance ohmmeter should have a range of?

If during an initial verification on an installation, a continuity of cpc test gives erroneous results, you should?

A low resistance ohmmeter should provide a short circuit current not less than?

One test that will commonly identify short circuits within an electrical installation is the?

Which of the following would NOT be acceptable for performing an insulation resistance test?

The insulation resistance test voltage for a 230v installation is?

Which of the following tests should be performed specifically on a three-phase circuit?

Why should the circuit protective conductor be tested before the insulation resistance test?

An intrinsically safe test instrument would be used in?

A test instrument has a calibration date that has passed what should be your course of action?

Why is it important to test a new installation in the correct sequence?

The test designed to determine the correct connection of all the protective conductors within installation is known as the?

A low reading ohmmeter used to perform a continuity of protective conductor test, should record results in?

Before using a multifunction test instrument, what is the MOST important thing should you check for?

To maintain accurate readings, an instrument should?

Test probes to the standards of GS38, should amongst other considerations...

The insulation resistance test voltage for a 400v installation is?

It is recommended that test instruments are nulled to?

Failure to get a reading of polarity using test method one could indicate?

During an Insulation Resistance test, to detect any contact between a live conductor and any 'unearthed' metalwork, which of the following should be done prior?

The correct scale for a multifunction tester, when measuring R1+R2 is?

The test voltage of a low resistance ohmmeter recommended by GN3 should be within?

Without in-house checks, test instruments should ideally be calibrated at least?

An insulation resistance test on a large industrial installation is carried out using?

An insulation resistance test should record results in?

If two cables are connected together in series and measured, the overall resistance will?

The reading in the picture was obtained during an insulation resistance test between phase, neutral and CPC. What might be the result most likely mean?

If two different sized cables were connected together in parallel and measured using a low resistance ohmmeter, the overall resistance will

Polarity can be tested prior to energising using a?

If two bonding conductors of equal length, were connected in parallel the resistance would?

The following tests are classed as dead tests, what is the correct sequence according to GN3? 1. Continuity of R1+R2 2. Polarity 3. Insulation resistance 4. Continuity of CPC

If a copper busbar is drawing a current of 300A, what will be the physical effect on the actual busbar?

During a continuity of Ring final conductors test, 10 Sockets give a R1+R2 reading of 0.68Ω but one socket gives a reading of 0.92Ω. What might that indicate?

A surge protective device installed as part of a circuit, should necessitate?

An insulation resistance test on a small installation that contains no distribution circuits, can be?

If three conductors equal in length and with a resistance of 0.15Ω are connected in series, what is the total resistance?

The reading in the picture was obtained during an insulation resistance test between phase and neutral. What might the result most likely mean?

When performing an insulation resistance test on a large installation, it is a good idea to subdivide circuits to avoid?

If a copper conductor was halved in length, the resistance would?

The minimum insulation resistance value for a 230v installation, required by the IET BS7671 Wiring Regulations is?

An R1+R2 reading is taken on a standard lighting circuit, what instrument should be used?

A continuity of ring final conductors test is carried out using a low resistance ohmmeter, for what reason?

Test method 2 is an effective method of measuring?

The minimum insulation resistance value for a SELV installation, required by BS7671 IET wiring regulations is?

The first test performed on an initial verification is continuity of protective conductors, what instruments should be used for this test?

If the temperature of a conductor decreases, the resistance?

During an insulation resistance test on a lighting circuit that contains intermediate switching on three different levels of stairs, what should you ensure?

Prior to performing an insulation resistance test, you should?

A SELV circuit should be insulated resistance tested?

A polarity test is conducted to verify that?

During one of the test methods for the continuity of CPC, GN3 recommends a temporary link should be made?

If 3 conductors equal in length and with a resistance of 1.5Ω are connected in parallel, what is the total resistance?

Prior to performing an insulation resistance test, you should?

The setting indicated in the picture is used for what particular test?

Several test instruments are used on an installation, which of the following may give a reading of 0.48Ω

If the ambient temperature increases, the conductor resistance?

For an initial verification, performing the continuity of bonding conductors should be done with one end disconnected to?

The long lead method used to determine continuity of protective conductors for a circuit, should have a result recorded in which column?

The resistance of a bonding conductor will increase if?

The scale indicated in the picture is used for the?

A test of continuity at each socket-outlet of a ring final circuit is carried out to ensure that?

The responsibility for giving the next inspection and testing date on an EICR lays upon on?

The responsibility for giving the next inspection and testing date on an EIC lays upon on?

An Electrical Installation Certificate must indicate which responsibility for an installation?

One of the requirements for initial verification on a completed installation is?

When performing an initial verification on an installation, why do we not record "X" on the schedule of inspections?

A reference method indicates?

One of the requirements for initial verification on a completed installation is?

Guidance Note 3 recommends an accuracy of digital test instruments of?

Before you begin testing an installation, the designer has indicated that the method of protection against fault contact is ADS. What does this mean?

A new installation is to be inspected and tested by yourself. What information could you have available before you start testing?

Why is it important to keep records of test equipment usually via serial numbers?

HSE Guidance Notes GS38 give particular guidance to?

On completion of an initial verification on a domestic property, the customer should receive?

According to BS7671 an electrical installation certificate should be signed by?

According to the EAWR, an inspector must have?

You have been sent to a job to complete a full initial verification on a large office block. Which of the following items you have been given is unnecessary at this point?

A new installation is to be inspected and tested by yourself. What information should you have available before you start?

For an existing installation, which of the following should be made available to the person conducting the inspection and test?

Periodic inspection and testing of an installation should be completed by?

Initial Verification of an installation should be completed by?

BS7671 gives guidance on the installation of electrical systems. Although it is not a statute document it closely interprets?

The Health and Safety Executive publish a document for guidance on electrical test equipment known as?

Which one of the following items is included in the inspection checklist, during the initial verification of an installation?

On the completion of an initial verification, what should the inspector do with the paperwork?

One of the requirements for initial verification on a completed installation is?

A new installation is to be inspected and tested by yourself. What information should you have available before you start?

A new installation is to be inspected and tested by yourself. What piece of information should you have available before you start?

BS7671 has a separate part designated solely to Inspection and Testing. The legal status of this document is that it is a?

The term Duty holder used in the Electricity at work Regulations, refers to the person?

Which one of the following reasons, would require an Electrical Installation Condition Report?

Which one of the following reasons would require a periodic inspection and test?

Which one of the following reasons, would require an Electrical Installation Certificate?

Which one of the following reasons, would a Minor Electrical Installation Works Certificate be completed for?

An Electrical Installation Condition Report is completed?

An Electrical Installation Certificate is completed?

Which one of the following reasons would require an initial verification?

Which of the following information would an inspector require before carrying out an initial verification?

The person responsible for an electrical system is known as?

What two documents must accompany an EIC for it to be valid?

Which one of the following, is a characteristic of the supply which must be recorded on an Electrical Installation Certificate?

Which one of the following, is a characteristic of the supply which must be recorded on an Electrical Installation Certificate?

Which one of the following, is a characteristic of the supply which must be recorded on an Electrical Installation Certificate.

Which one of the following, is a characteristic of the supply which must be recorded on an Electrical Installation Certificate?

Which one of the following, is a characteristic of the supply which must be recorded on an Electrical Installation Certificate?

What documents must accompany an EICR for it to be valid?

What is not recorded on an EICR?

What information relating to the circuit protective devices needs to be recorded on the schedule of circuit details?

What information relating to the circuit protective devices needs to be recorded on the schedule of circuit details?

The existing installation in a supermarket is to be inspected and tested as a requirement of the insuarance policy. Previous inspection and testing records exist but two additional lighting circuits has been installed which there are test results available. Which test can be carried out without the use of GS38 compliant test leads?